Custom Workflow
Last updated
Was this helpful?
Last updated
Was this helpful?
Autolaunch requires additional BaseSpace Sequence Hub and sample sheet settings.
Autolaunch uses the BaseSpace Sequence Hub (BSSH) run planning tool to create and export a v2 format sample sheet to enable streaming of sequencing run data to the project and requires the following additional settings. See Figure 1 (below).
Access to BaseSpace Sequence Hub.
ICA Run Storage is enabled under BaseSpace Sequence Hub settings.
Refer to the BaseSpace Sequence Hub support site page for information on .
Autolaunch requires a v2 format sample sheet with specific parameters that instruct the BSSH project to automatically initiate a Heme pipeline analysis in ICA. Use the run planning option in BaseSpace Sequence Hub to generate the sample sheet. The exported sample sheet is automatically populated with the required fields. Using an invalid sample sheet can result in failed runs and analyses.
Refer to Table 1 (below) for descriptions of the added fields. Enter the following required run parameters in BaseSpace Sequence Hub Run Planning:
Secondary Analysis
BaseSpace Sequence Hub / Illumina Connected Analytics
Application
DRAGEN Heme App for Whole-genome Sequencing
For more information on run planning, refer to the the
The BaseSpace Sequence Hub setting for run monitoring and storage must be selected on the instrument to use Heme pipeline Analysis Software analysis Autolaunch. For information on preparing your instrument for DRAGEN Heme App for Whole-Genome Sequencing Analysis Software Autolaunch, refer to the documentation for your instrument.
Use Run Planning in BaseSpace Sequence Hub to create and export a sample sheet.
Import the sample sheet to the instrument and start the sequencing run. Data is uploaded to BaseSpace Sequence Hub and then pushed to ICA. You can monitor the run in BaseSpace Sequence Hub.
When sequencing and the upload completes, analysis autolaunches in ICA. You can monitor the status of the analysis in BaseSpace Sequence Hub or ICA
If necessary, requeue the analysis via the run's Summary page in BaseSpace Sequence Hub. Refer to the BaseSpace Sequence Hub support site page for more information on requeuing an analysis.
View the analysis output results in either BaseSpace Sequence Hub or ICA.
Table 1. Additional Sample Sheet Fields for Autolaunch
Autolaunch-compatible sample sheets contain the following fields specific to autolaunch configuration.
Cloud_Heme_Data
Sample_ID
The unique ID to identify a sample. Must match a Sample_ID used in the Heme_Data section.
Yes
Sample_Type
Sample type.
No
Sample_Description
Must meet the following requirements:
No
- 1–70 characters.
- Alpha numeric characters with underscores, No dashes and spaces. If you enter an underscore, dash, or space, enter an alphanumeric character before and after.
Cloud_Heme_Settings
SoftwareVersion
The Heme software version
No
StartsFromFastq
Set the value to TRUE or FALSE. If autolaunching from BCL files, this must be set to FALSE.
Yes
Cloud_Data
Sample_ID
The same sample ID used in the Cloud_Heme_Data section.
No
ProjectName
The BaseSpace Sequence Hub project name.
No
LibraryName
Combination of sample ID and index values in the No following format: sampleID_Index_Index2.
No
LibraryPrepKitName
The Library Prep Kit used.
No
IndexAdapterKitName
The Index Adapter Kit used.
No
Cloud_Settings
GeneratedVersion
The cloud GSS version used to create the sample sheet. Optional if manually updating a sample sheet.
No
CloudWorkflow
ica_workflow_1
Yes
Cloud_Heme_Pipeline
Yes
This value is a universal record number (URN). The valid value is defined in